Electrical practice questions
10 original sample questions on electrical. Pick an answer, then open the explanation. Review the electrical study notes first if you like.
1. A GFCI breaker is identified by:
- A test button
- A larger size
- A red handle
- Two poles only
Show answer & explanation
Answer: A. A test button
GFCI breakers have test buttons.
2. 12 AWG copper branch circuit conductors are typically protected by a breaker of:
- 30 amps
- 40 amps
- 50 amps
- 20 amps
Show answer & explanation
Answer: D. 20 amps
Common sizing: 14 AWG copper on 15 A, 12 AWG on 20 A, 10 AWG on 30 A.
3. 14 AWG copper wire on a 30-amp breaker indicates:
- A breaker that is too small
- A ground fault on the circuit
- Correct sizing for heavy loads
- Overcurrent protection exceeds wire capacity
Show answer & explanation
Answer: D. Overcurrent protection exceeds wire capacity
14 AWG copper is usually limited to 15 amps.
4. A GFCI device protects people by detecting:
- Loose connections that arc in walls
- Overloaded circuits drawing high current at startup
- Voltage spikes from lightning
- Current imbalance between hot and neutral
Show answer & explanation
Answer: D. Current imbalance between hot and neutral
GFCIs trip on small leakage current. (General reference: NEC 210.8 (GFCI protection); local adoption varies.)
5. A 'double-tapped' breaker means:
- Two breakers are tied together with a handle tie
- A breaker that serves outlets in two different rooms
- Two conductors are under a terminal designed for only one
- A breaker has tripped twice
Show answer & explanation
Answer: C. Two conductors are under a terminal designed for only one
Most breakers are listed for one conductor. Two can loosen and overheat, so report it as a defect.
6. A bedroom circuit lacks AFCI protection in a home built in the 1980s. The best report statement is:
- Older homes cannot have AFCI breakers installed
- AFCI not present; consider upgrade for added safety
- The circuit is defective and must be disconnected now
- AFCI is required by law in every older home immediately
Show answer & explanation
Answer: B. AFCI not present; consider upgrade for added safety
AFCIs may not have been required when built; recommend as a safety upgrade. (General reference: NEC 210.12 (AFCI protection); local adoption varies.)
7. A burned smell or scorched receptacle indicates:
- Normal operation under load
- Dust burning off a new device
- Overheating and a fire hazard
- New paint drying on the plate
Show answer & explanation
Answer: C. Overheating and a fire hazard
Report heat damage.
8. A double-pole breaker serves a 240-volt water heater with one handle tripped and the other on. This most likely indicates:
- Normal operation of a 240-volt circuit breaker
- The water heater uses 120 volts on each side
- The breaker is a GFCI type that has been tested
- A breaker that is not common-trip; evaluate
Show answer & explanation
Answer: D. A breaker that is not common-trip; evaluate
Two-pole breakers should trip both legs together.
9. A ceiling fan that wobbles badly should be:
- Removed by the inspector
- Ignored since it still spins
- Reported for securing
- Painted in place
Show answer & explanation
Answer: C. Reported for securing
Loose fans can fall.
10. A main panel with a 200 A main fed by 2 AWG aluminum conductors may be:
- Ideal for heavy loads
- Undersized for the rating
- Correctly grounded
- Oversized for the breaker rating
Show answer & explanation
Answer: B. Undersized for the rating
Conductors must match the rating.
Original practice items for study only, not actual exam questions. Content may contain errors.