Property & Building Inspection practice questions
A mixed set of 10 original questions from this domain. Tasks covered: Site conditions, Exterior, Roof, Structure, Electrical, Cooling, Heating, Insulation, moisture & ventilation, Mechanical exhaust, Plumbing & fuel distribution, Interior, Fireplaces & fuel-burning appliances, Life safety.
1. A concrete driveway with a crack wider than 1/4 inch and vertical offset is best reported as:
- Normal for all new driveways
- A cosmetic item never reported
- A trip hazard needing repair
- Proof of foundation failure
Show answer & explanation
Answer: C. A trip hazard needing repair
Displacement creates a trip hazard. Report location and recommend repair by a qualified contractor.
2. A balcony with ponding water and soft decking near the house wall suggests:
- Possible concealed framing decay
- Recently sealed decking
- Normal wear only
- Proper drainage slope toward the home to protect the edges
Show answer & explanation
Answer: A. Possible concealed framing decay
Ponding and soft spots near the wall suggest water intrusion. Recommend evaluation, as concealed balcony framing failures can be serious.
3. A chimney cricket is used to:
- Vent attic air out through the chimney
- Divert water around a wide chimney
- Prevent birds from nesting in the flue
- Hold up the chimney crown in high winds
Show answer & explanation
Answer: B. Divert water around a wide chimney
Crickets prevent water and debris from collecting behind wide chimneys.
4. A basement wall shows a vertical crack that is wider at the bottom and dry, with a matching crack in the floor slab. This pattern may suggest:
- A roof leak running down the inside wall
- Normal shrinkage cracking with no movement of any kind
- Settlement near that area; evaluation recommended
- An electrical problem behind the wall
Show answer & explanation
Answer: C. Settlement near that area; evaluation recommended
Wider-at-bottom cracks can indicate movement.
5. A 14 AWG copper branch circuit protected by a 30-amp breaker is an example of:
- Proper sizing
- Reversed polarity at the receptacle
- A bonding jumper
- Overfusing (overcurrent protection too large for the wire)
Show answer & explanation
Answer: D. Overfusing (overcurrent protection too large for the wire)
14 AWG copper is typically limited to 15 amps. An oversized breaker lets the wire overheat before tripping.
6. A clogged condensate trap can cause:
- Water overflow
- Less noise
- Lower humidity
- More cooling
Show answer & explanation
Answer: A. Water overflow
Clogs back up water.
7. A boiler expansion tank that is waterlogged may cause:
- Pressure swings and relief valve discharge
- Lower energy use
- Better heat output
- Quieter operation
Show answer & explanation
Answer: A. Pressure swings and relief valve discharge
Expansion tanks absorb pressure changes.
8. A basement rim joist area is insulated with exposed foam plastic with no covering in a finished space. The concern is:
- Exposed foam improves fire safety in basements
- Foam on rim joists is never permitted anywhere
- Foam plastic generally needs a thermal barrier
- Rim joists should never be insulated at all
Show answer & explanation
Answer: C. Foam plastic generally needs a thermal barrier
Many foams require covering for fire protection.
9. A bath fan duct runs uphill then down to a wall cap and water drips from the fan grille in winter. The likely cause is:
- A plumbing leak above
- Condensation collecting in the duct
- Rain entering through the wall cap
- A defective fan motor
Show answer & explanation
Answer: B. Condensation collecting in the duct
Moist air condenses in cold ducts; slope and insulate.
10. A dishwasher drain hose runs flat along the cabinet floor to the disposal with no high loop or air gap. The concern is:
- Wastewater can back-siphon into the dishwasher
- The disposal will run constantly
- The dishwasher will drain far too quickly into the sink
- The hose will freeze in winter
Show answer & explanation
Answer: A. Wastewater can back-siphon into the dishwasher
A high loop or air gap prevents backflow.